[Apr 11, 2026] Get Latest and 100% Accurate IN101_V7 Exam Questions [Q47-Q62]

Share

[Apr 11, 2026] Get Latest and 100% Accurate IN101_V7 Exam Questions

Maximum Grades By Making ready With IN101_V7 Dumps

NEW QUESTION # 47
A radio station transmits an omnidirectional signal that is received by multiple radios. What type of transmission method is used in this example?

  • A. Half-duplex
  • B. Simplex
  • C. Full-duplex

Answer: B


NEW QUESTION # 48
Which of the following steps should be performed first when terminating a coaxial cable?

  • A. Verify connector type
  • B. Cut the cable
  • C. Strip the cable
  • D. Fold back the braiding

Answer: A


NEW QUESTION # 49
How long does it take someone to form a first impression?

  • A. 1 to 2 minutes
  • B. 30 minutes to 1 hour
  • C. 5 to 10 minutes
  • D. 10 to 15 seconds

Answer: D


NEW QUESTION # 50
A category 8 cable is terminated into category 6A outlets with category 5e patch cords. What is the maximum supported performance level?

  • A. Category 7
  • B. Category 6A
  • C. Category 5e
  • D. Category 8

Answer: C


NEW QUESTION # 51
Which of the following is used to equalize potential differences between the SBB on the same floor?

  • A. TBB
  • B. RBB
  • C. BBC
  • D. TEBC

Answer: C


NEW QUESTION # 52
Which of the following topologies is the recommended topology for distribution systems in campus environments?

  • A. Hierarchical Star
  • B. Tree
  • C. Star
  • D. Ring

Answer: A


NEW QUESTION # 53
Which of the following attachment methods does BICSI recommend for attaching coaxial connectors to coaxial cable?

  • A. Push-on
  • B. Screw-on
  • C. Crimp
  • D. Compression

Answer: D


NEW QUESTION # 54
Which of the following is the first step of the emergency rescue process?

  • A. Secure the area
  • B. Survey the scene
  • C. Contact 911
  • D. Notify someone

Answer: B


NEW QUESTION # 55
Which of the following is used to express system gain and loss?

  • A. Decibel (dB)
  • B. Farads
  • C. Ohms
  • D. Henries

Answer: A


NEW QUESTION # 56
Which of the following is used to perform continuity and length tests for coaxial cable?

  • A. TDR (Time domain reflectometer) with an adapter
  • B. OLTS (optical loss test set)
  • C. VFL (visual fault locator)
  • D. OTDR (optical time domain reflectometer

Answer: A


NEW QUESTION # 57
What is the minimum recommended amount of vertical clearance for open-top cable supports?

  • A. 75 mm (3")
  • B. 125 mm (5")
  • C. 150 mm (6")
  • D. 100 mm (4")

Answer: A


NEW QUESTION # 58
You are pre-terminating cable. Where should the labels be placed?

  • A. Far end
  • B. Both ends
  • C. Near end

Answer: B


NEW QUESTION # 59
Which of the following is permissible if the available firestop assembly is NOT capable of properly restoring the necessary fire rating?

  • A. Substitute products from another assembly
  • B. Move the installation to another location
  • C. Obtain written assistance from the manufacturer
  • D. Add more of the product to increase the rating

Answer: C


NEW QUESTION # 60
What is the markings for non-conductive optical fiber riser cable?

  • A. OFNR
  • B. OFCR
  • C. OFNP
  • D. OFNG

Answer: A


NEW QUESTION # 61
What is the maximum allowable horizontal cable length?

  • A. 90 m (295')
  • B. 50 m (164')
  • C. 10 m (33 ')
  • D. 30 m (100')

Answer: A


NEW QUESTION # 62
......

Give push to your success with IN101_V7 exam questions: https://troytec.dumpstorrent.com/IN101_V7-exam-prep.html